Labotect C-Top Incubator with SAFE Sens® pH Monitoring – IVFSynergy

Labotect C-Top Incubator with SAFE Sens® pH Monitoring


For more information or a quote on this item please email IVFSynergy

Below you will find some useful product details


REF 16377

Benchtop incubator with integrated SAFE Sens® technology for continuous, non-invasive pH monitoring

Advantages of Labo C-Top with SAFE Sens® pH monitoring:

  • All advantages and options of Labo C-Top combined with state of the art pH monitoring system
  • Independent monitoring of the pH-value in C-Top chambers
  • TrakPods™ integrated into the surface of Labo C-Top without the use of valuable dish space
  • Real time monitoring of the pH-value every minute or every 30 minutes for up to 7 days
  • Accurate measurements: ± 0.05 in a range of pH 7.00 to 7.60
  • SAFE Sens® measurement technology utilizes a patented and proven LED-based optical fluorescent system
  • Included Software for data recording capabilities and automatic alerts (by e-mail)
  • Monitoring of up to 8 chambers with one TrakStation™

 

Features:

pH value

Accurate measurements: ± 0.05 in a range of pH 7.00 to 7.60
Changes of pH immediately visible due to continuous monitoring

Non-invasive

No petri-dish required

Monitoring without staff intervention and lid opening

Calibration

No costly, time consuming calibration required:

·         One qc2 alignment tool needed per laboratory

·         Automatically adjusts the fluorescent signal to restore to factory settings

·         No outside calibration services required

·         No incubator down time

Options

Integrated SAFE Sens® TrakPod™ either on both sides or side of choice

With or without SAFE Sens® TrakStation™

PC software LaboDat+ for documentation of incubator’s parameters
Second gas inlet for use of different gas mixtures for each chamber
Lockable lids

Interfaces

Remote alarm (potential free)
RS485-interface for data logging with optional available PC software LaboDat+

Technical Data:

Exterior

Dimensions 403 x 225 x 155 mm (w x d x h)
Weight 8.8 kg

Interior

Two chambers with 0.5 litres each
Mixed load possible

Temperature

Overall heating from the top and bottom of each chamber
Range 30 °C - 42 °C from 7 °C above 
ambient temperature
Stability / uniformity ± 0.1 °C / ± 0.3 °C

Gassing

Premixed gas
Gas flow adjustable between 20 ml/min and 30 ml/min
Flow rate after opening the lid (automatic gas purge):
250 ml/min for 3 minutes

Power Supply

110 – 230 V AC, 50/60 Hz, 100 VA 
Primary pressure for gas 0.8 bar
Ambient temperature 18 °C - 30 °C

Classification

Safety class I
Class IIa for every usage according to EC-Directive 93/42/EEC
EN 61010 conform

 

Options: 

  • REF 16377: Labo C-Top with SAFE Sens® pH monitoring system

Integrated Trakpods™ either on both sides or on one side of choice

  • REF 16374: SAFE Sens® TrakStation™
  • REF 16370: SAFE Sens® sterile sv2-sensor (10 pieces)
  • REF 16371: SAFE Sens® qc2 alignment tool
  • Labo C-Top with SAFE Sens® pH monitoring and lockable lids
Higher security for your cultures
Limited access to the cultures
  •  Labo C-Top with SAFE Sens® pH monitoring and second gas inlet

 Every chamber to be gassed with different mixtures at the same time

 

 C-Top_SafeSens_Brochure.pdf